- What is valve Packing
 - Applications
 - Products
 - Installation
 - Advantages
 
What is Valve Packing?
Product recommended for flush free pump service with leak free performance in most applications;Contact the Nekhil Incorporate for Specific recommnedations

Applications
- Gate Valves
 - Globe Valves
 - Pinch Valves
 - Diaphram Valves
 - Needle Valves
 - Plug Valves
 - Butterfly Valves
 - Ball Valves
 - Check Valves
 - Relief Valves
 - Control Valves
 - Knife Valves
 
Prodcuts

3300C – Slade’s Cost Effective Pump and Valve Packing
3300G – Slade’s Best All Purpose Pump and Valve Packing
300W - Slade''s Best Valve Packing
3300CJ - Slade''s Anti-Extrusion Carbon Fiber Packing
Installation
- Check clearances and dimensions
 - Best to use no more than 5 sealing rings in stuffing box (use Slade”s Enviro-Foil Spacer Bushings to reduce rings)
 - Cut sealing rings on the bias (45° angle), stagger joints
 - Compress each sealing ring 25%-30% (use packing compressors as needed). Do not compress spacer bushings.
 - Loosen gland to allow it to relax
 - Snug the gland bolts
 

Advantages
Fire Safe
- Slade braided graphite foil is API Fire Test Certified
 - API 589 First Edition
 - API 607 Fourth Edition (modified by EXXON Specs)
 - Tested by Southwest Research Institute
 - Witnessed by 3 EXXON Engineers
 - Temperatures to 1800°F/1000°C
 - Tested at 5% of allowable standard
 - Performed under a grant from the American Petroleum Institute
 - Warning: Valves sealed with packings containing lubricants or blocking agents (PTFE) may cause secondary fires when exposed to the intense heat of a fire in another unit, which would cause packing shrinkage and leakage of flammable fluids causing a secondary fire.
 - SLADE Patented Packings: rated FIRE SAFE
 
Emission Safe
- PERF Emission Standards
 - Contact Slade for documentation
 - EXXON-Emission Report:
- Emission tests, performed at a leading petroleum company”s test facility in Florham Park, NJ (using PERF procedures and standards), show that Slade patented, reinforced braided graphite foil outperformed standard die-formed graphite sealing rings.
 - Slade reduced emissions by 74%.
 
 - Corpus Report:
- A major Gulf Coast, USA refinery reports that 96% of the 325 valves packed with slade reported zero ppm emissions. Most of these valves were packed in the field by inexperienced installers.
 
 - Cambridge Report:
- A major USA West Coast refinery reports that after 5 years, 96% of the 282 field installed valves were at zero emissions and that the 3,000 psi hydrogen control valves never went over 9 ppm during the 5 year test. Most of these valves were packed in the field.
 
 